Category     

NCOS: Using Temperature Control on Supported Cradlepoint Products

« Go Back

Information

 
Content

NCOS: Using Temperature Control on Supported Cradlepoint Products

Products Supported: AER31x0, IBR1100, IBR1150. Click here to identify your router.

NCOS Version: 6.0 or later - for information on upgrading NCOS, click here.


Quick Links

Summary

Configuration of Alerts

Related Articles


Summary

One feature of the Cradlepoint IBR11X0 and AER3100 product line is an internal hardware temperature sensor. This temperature sensor allows NCOS to monitor the router's internal temperature, as well as monitoring the modem's temperature. This functionality provides several options that can greatly assist the management of Cradlepoint devices in especially hot or cold environments.

Using Cradlepoint's temperature control functionality requires a device that includes a hardware temperature sensor. At the time of this writing (May 2015) the Cradlepoint COR IBR1100 and IBR1150 and AER3100 devices include this feature. The temperature sensor is part of the router's hardware and is always enabled.

Devices that include a temperature sensor will indicate on the DASHBOARD, the router's current temperature (in Celsius) as well as the high and low temperatures observed over the previous 24 hours.

User-added image

If the router exceeds 80 degrees Celsius, the router will automatically shut down wireless (WiFi) functionality to attempt to bring the router back within threshold. If the router remains above the threshold, then the cellular modem will also be temporarily disabled. After the router's temperature has decreased to 78 degrees Celsius, the router will re-enable the cellular and WiFi radios again.

Under no circumstance will the temperature sensor power the router off!

The temperature of the router and the modem and alert configuration options can be accessed at SYSTEM > Administration > Temperature.

User-added image

Temperature control functionality provides options for configuring alerts & logging for when the router temperature drops below a specified minimum temperature or exceeds a maximum specified temperature. The directions below show how to configure notification alerts for then the router has exceed the minimum or maximum specified temperatures.


Configuration of Alerts

Configuration Difficulty: Easy
  • Step 1: Log into the NCOS Setup Page. For help with logging in please click here.
  • Step 2: Click on SYSTEM, select the Administration sub-menu, and choose Temperature.
  • Step 3: Enter values for the "Minimum Temperature" and "Maximum Temperature" fields. The default minimum temperature is 10 degrees Celsius, and the default maximum temperature is 70 degrees Celsius.
  • Step 4: Click Save to save your settings.

User-added image

After making this change, as long as alerting is enabled, the router will send alerts if the router drops below the minimum temperature or above the maximum temperature.


Related Articles


Published Date: 7/13/2017

This article not have what you need?  Not find what you were looking for?  Think this article can be improved?  Please let us know at suggestions@cradlepoint.com
 


 